×

Hello!

Welcome to text me on WhatsApp or send me an email to silvia@xyelectron.com

× Text me on whatsapp

Home >  hydraulic-solenoid-coil

SB618
Link: SB618    2018-01-25
SB617
Link: SB617    2021-05-27
Related

"Hydraulic Solenoid Coil"

Blog
about freon valves
2020-11-24
SB125 Freon Solenoid ValveFeatures :Commonly used for control of freon in industrial refigerationScrew type and welding type optionalGood water-proof,heat-proof characteristicVarious connection and voltages made to order of clientsOEM solenoid valve has urea pump solenoid valve, freon valves,latch solenoid valves,truck solenoid valve,bistable solen... SB125 Freon Solenoid ValveFeatures :Commonly used for control of freon in industrial refigerationScrew type and welding type optionalGood water-proof,heat-proof characteristicVarious connection and voltages made to order of clientsOEM solenoid valve has urea pump solenoid valve, freon valves,latch solenoid valves,truck solenoid valve,bistable solenoid valves,LPG valves,fluid control valves,cooling system valves,inox valves,Automotive valve.https://www.xyelectron.com/oem-automobile-valves/ View Details
pneumatic solenoid coil
2020-11-09
XINGYURFS is the manufacturer of the CE solenoid coils,pneumatic solenoid coil,ATEX/IEC flameproof coils,22mm coils,UL solenoid coil,electromagnetic coil,solenoid coils for solenoid valves.The limit switch box can be mounted on the pneumatic actuator directly,GT actuators,indicate the pneumatic rotary actuator open and close.ATEX explosion-proof pn... XINGYURFS is the manufacturer of the CE solenoid coils,pneumatic solenoid coil,ATEX/IEC flameproof coils,22mm coils,UL solenoid coil,electromagnetic coil,solenoid coils for solenoid valves.The limit switch box can be mounted on the pneumatic actuator directly,GT actuators,indicate the pneumatic rotary actuator open and close.ATEX explosion-proof pneumatic actuator have double acting,and single acting, body surface treatment is hard anodized.valve actuator for ball valve and butterfly valve.ISO5211 pneumaitc actuators have double acting and single acting type,output torque range of double acting type:2.78-13673. A rack and pinion actuators in the field of laser cutting machine transmission.https://www.xyelectron.com/coils/ View Details
hydraulic solenoid coil
2020-10-29
Control valve open and close.Xingyu offers a widely range of solneoid coils for different sizes armature.Welcome to enquiry.https://www.xyelectron.com/hydraulic-coil/... Control valve open and close.Xingyu offers a widely range of solneoid coils for different sizes armature.Welcome to enquiry.https://www.xyelectron.com/hydraulic-coil/ View Details
Why hydraulic solenoid coils burn-out?
2020-05-19
If the temperature of the coil increases what will happen to the directional control valve's function?"The short answer to this is: the solenoid coil will fail and therefore the hydraulic solenoid coilshydraulic solenoid coils itself will cease to function.In AC electric coils the resistance or impedance of the coil is lowest whe... If the temperature of the coil increases what will happen to the directional control valve's function?"The short answer to this is: the solenoid coil will fail and therefore the hydraulic solenoid coilshydraulic solenoid coils itself will cease to function.In AC electric coils the resistance or impedance of the coil is lowest when the solenoid is open, i.e. when the plunger is out. Impedance increases as the plunger is pulled into the closed position.As a result, the current draw of an AC solenoid is highest when the solenoid is open (plunger out) and lowest when the solenoid is closed (plunger in).The high current draw of an open AC solenoid is known as inrush current. And the current draw when the solenoid is closed is called holding current. AC solenoids can only dissipate the heat generated by their holding current. This means it's very important for the plunger to close completely when an AC solenoid is energized.In other words, the high inrush current generates more heat than can be continuously dissipated by the solenoid. So if the plunger is not able to be completely pulled into its coil - due to a mechanical problem with the valve for example, then the insulation around the coil windings will burn and the coil will short out.But what could go wrong with a hydraulic valve that would stop the solenoid plunger from being pulled in completely? Well, contamination is a common cause. When hard or soft particles invade the clearance between the spool and its bore, the solenoid may not have enough power to fully shift the valve's spool. This is often referred to as "silt-lock".If silt-lock is the problem, then replacing the solenoid is a waste of time. Replacing the entire valve will BUY some time - until it too becomes 'silt-locked'. The solution of course, is to get the contamination problem under control.Another problem presented by the inrush current characteristics of AC solenoids, is the possibility of overheating due to rapid cycling. Each time the solenoid is closed it is subject to the heating affect of the high inrush current. If the solenoid is switched on and off too rapidly, the successive inrush currents can generate more heat than can be dissipated, leading to failure of the solenoid.Still, an AC solenoid can be cycled quite rapidly. To give you some idea, a class H solenoid, which has insulation rated to 180C, can be safely switched twice per second. But a DC solenoid with class F insulation rated to 150C can be cycled four times per second without any fear of overheating. And the nice thing about DC solenoids is they don't burn out if the plunger doesn't completely close - due to silt lock or any other reason. View Details
close
certificate
Copyright © 2017 Xingyu Electron (Ning bo) Co., Ltd. All Rights Reserved.
Dsigned and Developed by www.hoogege.com